About Enercon
     Highlights
            Financial
            Installation Growth
        The Enercon Way
        Corporate Profile
        Enercon GmBH
        Customers
        Quality Assurance
        Enercon Tower
      Wind Energy
     Wind Resource Dept.
            Identification
            Scientific wind / weather
            Rigorous wind monitoring
            Wind flow modeling
            Optimized Micro-siting
            Wind farm monitoring
            Field testing
            Type Certifications
        Why Wind Energy
        Wind Scenario
        Wind Potential
      Carbon Credits
      Products
        E-53
        E-48
      Technology
       Product Technology
            Blade Technology
            Sync.Generator
            Brake System
            Grid Management
            Tower Technology
       Drive System
            Rotor Blade Concept
            Direct Drive
       Anular Generator
            General
            Stator & Rotor
            Enercon Control System
       Grid Connection
            Grid Connection System
            Enercon SCADA
            Main Control Unit
       Tower & Foundation
            Tower Construction
            Tabular Steel Tower
            Precast Concrete Tower
            Foundation Construction
        Research and Developement
      Projects
       Infrastructure
            Roads
            Power Evacuation
       Case Studies
            Low Wind Regime
            High Wind Regime
        Flagship Projects
        Wind Resource Monitoring
      Services
       O&M Services
            Enercon Services
            Customer Survey
            Enercon Care
            Value Focus
            Awards
            Spare Parts
        Financial Services
      Enercon IPPs
        Concept
        Role Of Enercon Power
        Operating WindFarm IPPs
      Human Resources
        Why Enercon
        S.H.E.
        Careers
      Training
        Training Academy
        Training Programs
        Road Map
      Login
        Customer Portal
        Employee
 

Synchronous Generator

This is a multi-pole variable speed generator. Due to this and Power electronics the Gear Box which steps up the speed to meet the speed of Induction Generator is eliminated resulting in reduced transmission losses, and elimination of wear and tear of the Gear Box and oil leakage associated with it The Rotor-Hub is directly connected to the Generator Rotor by the Axle pin thus eliminating the Gear Box and couplings. The speed of the generator Rotor is the speed of the Hub Rotor, which is 45 RPM maximum for E-33 and 31.5 RPM maximum for E-48. Thus it rotates at 40 and 30 times lower speed than the Gear Box type Turbines, hence, very low wear and tear.




The Synchronous Generator of Enercon with its electronics provides an excellent operational band width i.e. Voltage 415 ± 20% V Frequency 50 ± 5 Hz.

Pitch Regulation

Enercon Machines are continuous pitch regulated machines i.e., the Blade feathers on its axis as per the requirement of the angle of attack to achieve optimum efficiency at all wind speeds. Due to this the yield of the Electric Energy Generated is higher.
Reactive Power (RKVAH)

In case of Induction Generators the Reactive Power (RKVAH) Consumption is very high especially when the generation is low to medium, as well as these Turbines are a strain on the Grid systems of the State Electricity Boards.
They consume RKVAH to the extent of 45% to 60% of the kwh generated. The State Electricity Boards of Karnataka, Maharashtra, Tamil Nadu, Andhra Pradesh, Gujrat and Madhya Pradesh have imposed a penalty of Re 0.25 To Re 1.00 for drawl of every Unit of RKVAH which is an additional cost for the owners of the wind farms. Also the State Electricity Boards have to spend for additional capacitor banks at their sub-station to meet the requirements of Reactive Power whenever conventional types of Wind Energy Converters i.e., with Induction Generators are used.

Enercon's Synchronous Generator with its power electronic helps in generating RKVAH the extent of 0.95 lead of the Active power which actually helps the Grid System, and drawal of RKVAH is marginal.

Salient features of the Enercon Technology:

The Enercon machine employs three independent Aerodynamic Brakes. Each Blade turns on its own axis simultaneously and comes to such a position that the airflow is almost bypassed i.e., the lift force is considerably reduced, thereby bringing the Turbine to almost standstill condition.



   

News

Enercon India Limited

Testimonials

We are maintaining a very cordial relationship with Enercon ever since our first project in Wind energy. They have a dynamic, dedicated and professional team to take care of the investors...


Case Studies

We are very happy and would like to appreciate the joint efforts...

 
 
Home | Careers | Site Map | Disclaimer | Privacy Policy | Contact Us
Site best viewed in 1024 x 768 and above. © 2007 Enercon India Limited.
Powered By : Coconut Softwares Pvt Ltd.